EN
Carrying out menu settings
Switching on the torque wrench
Press any button for approx. one second.
The software version number is displayed in the
display.
In the following cases, it can take about one minute
until the torque wrench is ready for operation after it
has been switched on:
The first time the torque wrench is put into
operation
If no rechargeable batteries have been put in for
over 30 minutes.
Press the OK button.
If the "Save values" function is switched on, the four-
digit bolting application number is displayed.
To confirm the bolting application, press the OK
button.
To create a new bolting application, proceed as
described on page 14.
The current torque value which is set is displayed. 
The "TARA!" symbol flashes in the display. The torque
wrench is tared.
After taring, the torque wrench is in its basic status.
Carrying out basic settings
Settings in delivery condition
The "Cut-out" function mode is set in delivery
condition.
The description of the functions assumes that the
torque wrench is in "basic status". This is the status
after switching on the torque wrench and completion
of the taring process.
Button lock
To protect the torque wrench from unintentional
changes in the menus, it is equipped with a button
lock.
If you want to make settings in the menus, you must
first cancel the button lock. Proceed as follows:
Briefly press the F button twice in succession.
Saving settings
If you have carried out settings in a menu item,
proceed as follows:
To accept the setting and return to basic status,
press the OK button.
To accept the setting and switch to a different menu
item, press the F button until the desired menu is
displayed.
Setting a torque value
Press the F button until the torque value is
displayed.
The set torque value flashes.
Use the arrow buttons to set the desired value.
Each time one of the arrow buttons is touched
briefly, the value is adjusted by one division step
within the permissible range. The value can be
adjusted quickly by pressing the arrow button
for a longer time.
Save the setting as described on page 13.
Setting a unit of measurement
On switching the unit of measurement, the
value of the current setting is automatically
converted.
A tt e n t ion
Material damage possible due to
incorrectly set values.
Make sure that the torque value which is set after
changing the unit of measurement is correct.
To set the unit of measurement, press the F button
until the unit of measurement is displayed.
The set unit of measurement flashes.
Use the arrow buttons to select the desired unit of
measurement.
Save the setting as described on page 13.