This kind of Wind-sensor must be wired to the control unit on the indicated terminals, without
respecting the polarity. Exceeding the set level the control unit will automatically perform the
command associated to the UP button of the remote control. So ensure that the rotation direction
corresponds correctly to the buttons of the remote control. If not it's absolutely necessary to set the
rotation direction. The "Wind-alarm" time is 8 minutes during which the control unit will not accept
any command. During the wind-alarm the blue led inside the control unit blinks.
This function is useful to check the correct connection to the control unit and the rotation direction in
case of wind-alarm.
Activate the TEST function, with the sequence B+C, C. The awning opens for 10 seconds and closes
briefly to confirm that the test mode is activated. Move the anemometer blades by hand, the motor
performs short moves in closing direction. If the direction is not right it's necessary to invert the rotation
direction. To quit the test mode press any button from the remote control. During the wind-alarm the
blue led inside the control unit is on.
B
+ C
WIND SENSOR WINDTEC SC
(BLUE BUS TDS - BLUE BUS TDS RX)
TEST FOR WIND-SENSOR (WINDTEC SC)
C
WINDTEC SC - Ref. A520010
36