SPECIAL COMMANDS (USING MODULES A510008)
This operation mode is useful when one intends to use the Blue Bus TDS module to control one or
more Cherubini A510008 expansion modules.
The Blue Bus TDS module is equipped with a current sensor able to manage switching off the exits
when the connected motor reaches the limit switch. To use this management mode, the L1 terminal of
the J1 connector on the Blue Bus TDS must be connected to the terminal 1 of the CN1 connector on the
A510008 module. If this management mode is not being used, the module controls the exits designed
for the motor with a standard time-out of 180 seconds.
"TIME-OUT" refers to the operation time of the control unit from the moment in which the command
is given (opening or closing). The opening/closing time of all the awnings connected must always be
shorter than the time-out time.
The time-out is set to zero only after a set time has elapsed or after a stop.
OPERATION MODE "DEAD MAN":
LOC CMD
DSW1 OFF
ON
1
2
3
4
5
OPERATION MODE "CONTINUOUS MOVEMENT":
LOC CMD
DSW1 ON
ON
1
2
3
4
5
TECHNICAL FEATURES
- Power supply
- Power consumption
- Max. motor power
- Operating temperature
- Weight
- Dimensions
- Degree of protection
ADDITIONAL FEATURES FOR BLUE BUS TDS RX
- Radio frequency
- Decoder system
- Modulation
- Max number storable transmitters
DOWN
down
DOWN
down
110 - 230 Vac
2 W
500 W
-10°C +55°C
300 g
80 x 80 x 45 mm (plastic case)
IP44 (plastic case)
433,92 MHz
Rolling Code
AM/ASK
15
time-out
180 sec
stop
LOC CMD
42
time-out
180 sec
stop