CONFIGURATION OF THE BLUE BUS TDS MODULE
The Dip Switch present on the module makes it possible to configure some functions.
Configurating the local command
Motor command "dead man"
ON
1
2
3
4
5
Motor command "continuous mode"
ON
1
2
3
4
5
Configuration of the centralized command
Timed or automatic transmission of the
centralized command
ON
1
2
3
4
5
Exclusively automatic transmission of the
centralized command
ON
1
2
3
4
5
Auxiliary "sensor" input configuration for rain sensor or WINDTEC SC wired wind sensor
with a normally open (NO) switch.
ON
1
2
3
4
5
ON
1
2
3
4
5
ON
1
2
3
4
5
Dip Switch 1 OFF
Dip Switch 1 ON
Dip Switch 2 OFF
Dip Switch 2 ON
Dip Switch 3 OFF
4 OFF
5 OFF
Dip Switch 3 ON
4 OFF
5 OFF
Dip Switch 3 ON
4 ON
5 OFF
The motor operates in the "dead man" mode. This
means that it moves as long as one of the LOC CMD
push buttons is kept pressed.
The motor works in the "continuous mode". This means
that it keeps moving even after one of the LOC CMD push
buttons has been released. To stop the movement of the
motor it is necessary to press any LOC CMD push button
once again or the STOP push button on the remote control.
The board which has received a centralized command
from the control switch or through the BUS controls
its own local motor and re-transmits the command to
the following board after 10 seconds (or earlier, if the
movement of the local motor has ended).
The board which has received a centralized command
from the control switch or through the BUS controls its
own local motor and re-transmits the command to the
following board only after the movement of the local
motor has ended.
Control of all the wired sensors is disabled.
Rain sensor active: closing the (NO) switch causes the
ascent of the awning.
Rain sensor active: closing the (NO) switch causes the
descent of the awning.
39