SPECIFICATIONS
CAUTION: CSA certified for use with only No. 1-K kerosene fuel.
Factory Tested: Kerosene, Diesel #1 and #2, Fuel Oil #1 and #2, JP8 (Jet A Fuel)
Model
50KR
Burn Rate:
50,000 Btu/hr (14.7 kW)
Fuel Rate:
0.37 gal/hr (1.4 L/hr)
Electrical Input:
115V, 60Hz, 3.5a
Line Protection:
10 amps
Min. Operating Voltage:
110V
Pressure Setting:
3.5 psig (24 kPa)
Max. Outlet Temperature: 1450
F (787
o
Fuel Tank Capacity:
4 gallons (15.1 L)
Ignition:
Direct Spark, Continuous Direct Spark, Continuous
Spark Generator:
Igniter 13 kV, 10ma
Primary Safety Control:
Solid State Control
Certification:

OPERATING PRECAUTIONS

This­is­a­kerosene,­direct-fired,­forced­air­heater.­It's­intended­use­
is­primarily­temporary­heating­of­buildings­under­construction,­
alteration­or­repair.
Direct-Fired­means­that­all­of­the­combustion­products­enter­the­
heated­space.­Even­though­this­heater­operates­very­close­to­100­
percent­combustion­efficiency,­it­still­produces­small­amounts­
of­carbon­monoxide.­Carbon­monoxide­(called­CO)­is­toxic.­CO­
can­build­up­in­a­heated­space­and­failure­to­provide­adequate­
ventilation­could­result­in­death.­The­symptoms­of­inadequate­
ventilation­are:
•­
headache­
•­
dizziness
•­
burning­eyes­and­nose­
•­
nausea
•­
dry­mouth­or­sore­throat
Be­sure­to­follow­advice­about­ventilation­in­the­Safety­
Precautions­section.
Forced­Air­means­that­a­blower­or­fan­pushes­the­air­through­the­
heater.­Proper­combustion­depends­upon­this­air­flow;­therefore,­
the­heater­must­not­be­revised,­modified­or­operated­with­
parts­removed­or­missing.­Likewise,­safety­systems­must­not­be­
circumvented­or­modified­in­order­to­operate­the­heater.
When­the­heater­is­to­be­operated­in­the­presence­of­other­people­
the­user­is­responsible­for­properly­acquainting­those­present­
with­the­safety­precautions­and­instructions,­and­of­the­hazards­
involved.

SAFETY PRECAUTIONS

1.­
Recommended­for­use­with­No.1-K­kerosene­fuel.­Factory­tested­
for­use­with­No.2-K­kerosene,­No.1­or­No.2­Diesel,­No.1­or­No.2­
fuel­oil­or­JP8­Jet­A­fuel­and­these­fuels­may­be­used­as­well.­Never­
use­gasoline,­biodiesel,­oil­drained­from­crank­cases,­naphtha,­
paint­thinners,­alcohol­or­any­other­highly­flammable­fuels.
2.­­ Check­the­heater­thoroughly­for­damage.­DO­NOT­operate­a­
damaged­heater.
3.­ DO­NOT­modify­the­heater­or­operate­a­heater­which­has­been­
modified­from­its­original­condition.
4.­ Suitable­for­either­outdoor­or­indoor­use­where­adequate­
ventilation­is­provided.­Never­use­in­areas­normally­for­
habitation.­Not­for­use­where­exposed­to­weather.
5.­ Use­in­well­ventilated­areas,­provide­at­least­2­sq.­ft.­(0.19­
sq.­m.)­of­opening­near­the­floor­and­2­sq.­ft.­(0.19­sq.­m.)­
near­the­ceiling­directly­to­outdoors.­Increase­air­openings­as­
marked­for­each­additional­heater.
80KTR
80,000 Btu/hr (23 kW)
0.55 gal/hr (2.1 L/hr)
115V, 60Hz, 4a
10 amps
110V
4.2 psig (29 kPa)
C)
1450
F (787
C)
o
o
o
6 gallons (22.7 L)
Igniter 13 kV, 10ma
Solid State Control
Mr. Heater, Inc.| Kerosene Forced Air Heater
140KTR
185KTR
140,000 Btu/hr (41 kW)
185,000 Btu/hr (54 kW)
0.96 gal./hr (3.5 L/hr)
1.3 gal/hr (5.0 L/hr)
115V, 60Hz, 5.5a
115V, 60Hz, 5.5a
20 amps
20 amps
110V
110V
5.0 psig (35 kPa)
6.8 psig (47 kPa)
1450
F (787
C)
1450
F (787
o
o
o
8.45 gallons (32 L)
13.5 gallons (51 L)
Direct Spark, Continuous
Direct Spark, Continuous
Igniter 13 kV, 10ma
Igniter 13 kV, 10ma
Solid State Control
Solid State Control
6.­ Always­keep­combustibles,­like­paper­and­wood­at­least­8­
ft.­(2.4­m)­from­the­heater­outlet­and­3­ft.­(1.0­m)­from­
the­top,­sides­and­inlet.­Locate­10­ft.­(3.0­m)­from­canvas­
or­plastic­coverings­and­secure­them­to­prevent­flapping­
movement.­
7.­
Caution:­Due­to­the­high­surface­and­exhaust­temperatures,­
adults­and­children­must­observe­clearances­to­avoid­burns­
or­clothing­ignition.­Do­Not­Touch.­Keep­children,­clothing,­
and­combustible­away.
8.­ Install­the­heater­such­that­it­is­not­directly­exposed­to­water­
spray,­rain­and­/­or­water.
9.­ Never­use­in­areas­normally­for­habitation­and­/or­where­
children­may­be­present.
10.­ Operate­only­on­a­stable,­level­surface.­(MH50KR­&­
MH80KTR­–­See­wood­floor­warning).
11.­ Do­not­use­with­duct­work.­Do­not­restrict­inlet­or­exit.
12.­ Use­only­with­electrical­power­specified.­The­electrical­
connection­and­grounding­must­comply­with­National­
Electrical­Code­–­ANSI/NFPA­70­(USA)­and­CSA­C22.1­
Canadian­Electrical­Code,­Part­1­(Canada).
13.­ Use­only­a­properly­grounded­3-prong­receptacle­or­
extension­cord.
14.­ Do­not­move,­handle,­or­service­while­hot­or­in­operation.
15.­ Use­only­in­accordance­with­local,­state­(provincial)­or­
national­requirements,­ordinances­and­codes.

OPERATING INSTRUCTIONS

UNPACKING
1.­ Remove­heater­from­carton.
2.­ Remove­all­protective­material­which­may­have­been­applied­
to­the­heater­for­shipment.
3.­ Check­the­heater­for­possible­shipping­damage.­If­any­
damage­is­found­immediately­contact­the­manufacturer­at­
800-251-0001.
ASSEMBLY (For­140,000,­185,000­and­210,000­BTU/hr­models­
only,­see­figure­1,­page­8.)
Wheels­and­handles­are­found­in­the­shipping­carton­along­with­
mounting­hardware.­The­wheels,­axle­and­mounting­hardware­
are­in­a­package.­Tools­required­are­a­5/16"­nut­driver,­3/8"­open­
or­adjustable­wrench­and­standard­pliers.
1.­ Assemble­the­wheels­onto­the­wheel­support­as­shown.
2.­ Install­one­of­the­cotter­pins­into­the­hole­on­one­end­of­
axle.
3
Operating Instructions and Owner's Manual
210KTR
210,000 Btu/hr (61.5 kW)
1.6 gal/hr (6.0 L/hr)
115V, 60Hz, 5.5a
20 amps
110V
8.4 psig (58 kPa)
C)
1450
F (787
C)
o
o
o
13.5 gallons (51 L)
Direct Spark, Continuous
Igniter 13 kV, 10ma
Solid State Control