pRe-InsTAllATIon InsTRUCTIons:
Please read ALL instructions before installing . We recommend that two people install this product . If a
new electrical outlet is required, have the outlet installed by a qualified electrician before installing unit .
step 1) Using the following table, find your wall-sleeve brand of your installation . If you cannot find
your your brand of sleeve listed in the table below, you can use whichever one is close in size and
configuration as a guide. There are two important guidelines to keep in mind:
A) The unit itself should be sloped somewhat toward the rear within the sleeve.
B) The unit should not rest flush with the bottom of a sleeve. Always use the 17" Tapered Spacer Blocks.
C) The unit should always have a sleeve. If you do not already own one, an Impecca Universal Sleeve
Model # ITA-US10 is available from www.impecca.com or your local dealer.
Brand
White-Westinghouse
Frigidaire
Carrier (52F Series)
General Electric
Hotpoint
Whirlpool
Whirlpool
noTe: All wall sleeves used to mount the new air conditioner must be in
sound structural condition and have a rear grille that securely attaches to
sleeve, or rear flange that serves as a stop for the air conditioner .
CAUTIon: When installation is complete, replacement unit MUST have a
rearward slope as shown .
step 2) Remove old air conditioner from wall sleeve and prepare wall sleeve as follows:
• Clean interior (do not disturb seals) .
• Wall sleeve must be securely fastened in wall before installing air conditioner .
• Drive more nails or screws through sleeve, into wall, if needed .
• Repair paint if needed .
step 3) Remove old air conditioner from wall sleeve and prepare wall sleeve as follows:
If a grounding wire is not already place, drill a 1/8 clearance hole for the grounding screw through left side
of wall sleeve, in a clear area about 3 inches maximum back from front edge of sleeve, using the grounding
screw and toothed washer .
Pull loose end of ground wire out front of sleeve, and temporarily bend it down and around lower edge of
sleeve . This ground wire will later be attached to frame of air conditioner once it is installed .
step 4) Begin specific wall sleeve preparations based on the instructions referenced in the above table .
Dimensions
W x H
Page
x D
25½" x 15¼" x
16" OR 17½"
17
OR 22"
26" x 15⅝"
14
x 15⅞
25⅞" x 16½"
15
x17⅛"
25⅞" x 16½"
16
x23"
Brand
Sears/Kenmore
Carrier(51S Series)
Fedders
Emerson
Fedders, Emerson
Friedrich
Fedders
Emerson
8
Dimensions
W x H
Page
x D
25¾" x 16⅞"
14
x 18⅝"
26¾"' x 15¾"
10
x 15"
27 x 16¾"
12
x 16¾"
27" x 16¾"
11
x19¾"