• To make the electrical connection and
fasten the drainpipe, place a wedge be-
tween the air conditioner and the wall
(see fig. 24).
• When you have finished, inspect carefully
to make sure there are no fissures at the
back of the air conditioner (the insulating
gasket must fit firmly against the wall)
particularly in the zone where air enters
and leaves the machine.
2.4.6 - Electric hook-up
The appliance is fitted with a power cord with plug
(Y-type connection).
If the socket is in proximity to the appliance, simply
plug it in.
Before connecting the conditioner, ensure that:
• The power supply voltage and frequency values comply with
those indicated on the data plate of the appliance.
• The power supply line is fitted with an efficient earth connection
that is appropriately sized for the maximum absorption of the
conditioner (minimum cross-section of the cable must be 1.5
mm2).
• The appliance is powered exclusively through a socket that is
compatible with the plug supplied.
Any replacement of the power cable must be carried out solely by
authorized technical support or by similarly qualified personnel.
On the power supply line of the appliance there must be an adequate
omnipolar disconnection device that complies with the national
installation regulations. It is, however, necessary to check that the
electrical power supply is equipped with efficient earthing and with
adequate protections against overloading and/or short circuits (a
type 10 AT delayed fuse or other devices with equivalent functions
are recommended).
24
EN - 21
UNICO