b.
After having cleared the fault, the service personnel will close the evacuation
pipe.
4.3 - DIAGNOSIS, ALARMS AND INCONVENIENCES
4.3.1 - Diagnosis of the inconveniences
It is important for the User to distinguish between functional problems and anomalies
in relation to the behaviour of the appliance as foreseen for its normal operation. Fur-
thermore, the most common problems may easily be solved through simple operations
on behalf of the User (See paragraph 4.3.5 - Anomalies and solutions).
For all the other reports (see paragraph: 4.3.3 - 4.3.4), it is necessary
to always contact the technical assistance service"
Any attempt to repair the appliance by unauthorised personnel will
immediately invalidate any form of guarantee.
4.3.2 - Functional aspects not to be mistaken for anomalies
The following events may occur during normal operation:
a.
The compressor does not start up again immediately after a stop (it takes
about three minutes to start again).
-
In the operating logic of the appliance a delay between a compressor stop
and its successive restart has been included, so that the compressor itself
is protected against activations that are too frequent.
b. During the heating operation of the heat pump appliances, the flow of hot
air may occur some minutes after activation of the compressor.
-
Should the fan start at the same time as the compressor, for the first few
minutes it would emit cold air into the room (and this could bother the occu-
pants) since the unit has not yet reached steady running conditions.
4.3.3 - Console led signals
In the event that the air conditioner is
blocked, the LEDs highlight an alarm
signal as per table "TAB1".
Contact an Olimpia service centre.
H
Reset key.
G
Infrared receiver.
EN - 38