WARNING: ELECTRICAL SHOCK HAZARD. Disconnect the power supply before performing service or
maintenance. Failure to do so may result in serious injury or death.
Daily
☑ Allow the cooling media to dry out completely once every 24 hours to prevent algae growth.
Weekly
☑ Check the cooling media for bowing, sagging, or dry streaks.
☑ Remove the cooling media (see page 6) and inspect the water reservoir. Remove any debris and make sure
the reservoir is clean.
☑ Check the water distribution system for leaks and check for clogged holes in the spray bar.
Bi-Weekly
☑ Clean the water reservoir every three days. See the following page for draining and cleaning instructions.
Monthly
☑ Add two water treatment tablets to the cooler's reservoir to avoid scale and mineral buildup (Fig. 1). Tablets
can be purchased at bigassfans.com. Tablets may need to be added more often if the water quality is poor.
Quarterly
☑ Drain and clean the water reservoir, water distribution system, and cooling media. See the following page for
draining and cleaning instructions.
☑ Check all cooler components for cracks or damage, including the pump and fan motor.
☑ Make sure the cooler's float valve automatically shuts off the water flow when the cooler is full.
Annually to every three years
☑ Replace the cooling media. Replacement cooling media can be purchased at bigassfans.com. The media
may need to be replaced more often if it becomes heavily stained with minerals or is damaged. See pages
6–7 for instructions on removing and installing cooling media.
Storing/winterizing
☑ Drain and clean the water reservoir, water distribution system, and cooling media. See the following page for
draining and cleaning instructions.
☑ To prevent freezing in the cooler's water line, disconnect the water supply, and then open the flow control
valve and the drain valve to dry out the reservoir.
☑ Store the cooler in a dry area and cover it to prevent damage and dust buildup. Storage covers can be
purchased at bigassfans.com.