22/03/23 – 15:35
Irr. F
Irr. BH
Irr. BL
[W/m2] [Off]
[Off]
754
22/03/23 – 15:35
Irr. F
Irr. BH
Irr. BL
[W/m2]
[W/m2]
[W/m2]
754
325
237
22/03/23 – 15:35
Irr. F
Irr. BH
Irr. BL
[W/m2]
[W/m2]
[W/m2]
754
3.
DISPLAY ENVIRONMENTAL PARAMETERS
VALUES
The instrument allows the real-time display of the modules' irradiance and
temperature values. The temperature measurement of the modules is
ONLY possible if it is coupled to a Master unit). The measurements are
performed using probes connected to it. It is also possible to measure the
angle of inclination of the modules (tilt angle).
1. Switch on the instrument by pressing key
2. Connect one reference cell HT305 to input INP1 in case of
Tmp/A
Monofacial modules. The instrument automatically detects the
[Off]
presence of the cell, providing the value of irradiance expressed in
W/m
2
. The screen to the side appears on the display
3. In case of Bifacial modules, connect the three reference cells HT305 to
the inputs INP1...INP3: (INP1 for Front Irr., and INP2 and INP3 for Back
Tmp/A
Irr.). The instrument automatically detects the presence of the cells,
[Off]
providing the corresponding values of irradiance expressed in W/m
The screen to the side appears on the display
4. Connect the PT305 temperature probe to the INP4 input. The instrument
recognizes the presence of the probe ONLY after being coupled to a
Tmp/A
Master instrument (see § 5.2.3) providing the module temperature
[°C]
value expressed in °C. The screen to the side is shown on the display
43
37
SOLAR03
.
2
.