Descargar Imprimir esta página

HT SOLAR03 Manual De Instrucciones página 36

Ocultar thumbs Ver también para SOLAR03:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 44
22/03/23 – 15:35
Irr. F
Irr. BH
Irr. BL
[W/m2]
[W/m2]
[W/m2]
754
5. Rest the remote unit onto the modules' surface. The instrument
automatically provides the value of the module's tilt angle with
respect to the horizontal plane, expressed in [°]. The screen to the
side appears on the display
Tmp/A
[Tilt]
25
The values read in real time are NOT saved in the internal
memory
4.
RECORDING VALUES OF PARAMETERS
The remote unit SOLAR03 allows saving in the instrument's internal
memory the references of the recordings over time of irradiance/
temperature values during a measuring campaign carried out by the
Master instrument to which it was associated.
Recording of irradiance/temperature values can ONLY be started
by the Master instrument associated with the remote unit.
The recorded values of irradiance/temperature CANNOT be
recalled on the remote unit's display, but can only be used by the
Master instrument, to which they are sent once measurements are
complete, to save STC values
1. Associate and connect the remote unit to the Master instrument via
Bluetooth connection (see the Master instrument's user manual and §
5.2.3). The symbol " " must turn on steadily on the display.
2. Connect the irradiance and temperature probes to the remote unit,
checking their values beforehand in real time (see § 5.3)
CAUTION
CAUTION
38
SOLAR03

Publicidad

loading