Technical Data
Description
Interfaces
Space requirement
Current measurement
Voltage measurement
Maximum cable length for USB interface
Energy manager input
External power supply (input)
External power supply (output)
Relay (voltage/load)
Storage temperature range
Operating temperature range
Type of the tested item
Description of the device function
Connection to the power supply
Installation/overvoltage category
Measuring category
Degree of contamination
Protection type
Value
2 x USB, 1 x PLC, 2 x WiFi, 2 x Ethernet, 12 x CT input,1 x RS485/CAN (not assigned)
11.5 pitch units (1 pitch unit corresponds to 17.5-18 mm/0.7 in.)
0.5 A to 600 A (depending on current converter), maximum cable length 3.0 m
100 V to 240 V (AC)
3.0 m
24 V (DC)/0.75 A
100 V to 240 V (AC)
24 V (DC)/18 W
Maximum 250 V (AC), maximum 3 A ohmic load
-40 °C to 70°C
-20 °C to 45 °C (at 10% to 90% humidity)
Control unit
Charging management for households
External power supply unit
III
III
2
IP20
Technical Data
31