COUNTING INSTANCE: WITH KNOWN THE SAMPLE'S QUANTITY AND THE UNIT WEIGHT
KEY (ORDER)
Press and Hold
[MENU] Key
Short Press [CAL] Key
Short Press [CAL] Key
Short Press [MENU]
key
Short Press [CAL] Key
Short Press [CAL] Key
Short Press [CAL] Key
Press and Hold [TARE]
Key
Quick restart: exit the present counting and restart a new counting. Press and hold (MENU) key can restart the step 1, short press (CAL) to
enter into step 3.
NOTE: The grey color words explain the signal's meaning which flash on the window..
78
STEP EXPLANATION
1. Enter Into Menu
2. Display counting Mode
3. Enter into Counting Program
4. Display Setting Menu
5. Flash Sample Quantity (Example: 20pcs)
•
Press [PRINT] key to cycle the sample quantity
setting O User can set sample quantity manually.
•
Press [UNIT] key to move the cursor and press
[PRINT] key to increase the number.
6. Flash Sample Unit Weight
•
User can set sample unit weight:
Press [UNIT] key to move the cursor and press
[PRINT] Key to increase the number.
7. The display will show the result
•
Three position to display the result as:
Upper left display quantity, Upper right display unit
weight: 0.1g, Main window display total weight
0.000g
8. Put any unknown numbers of pieces on pan and will
display a count. (Example: 300pcs)
Three position to display the result as:
Upper left display quantity 300pcs, Upper right
display unit weight: 0.1g, Main window display total
weight 30.000g
9. Exit the counting function.
USER'S MANUAL ABS
LCD SCREEN DISPLAY
--node-
-COUNT-
SANPLE
INPUT
0000020 pcs
0002.000
g
EN
MENU LEVEL
AND CODE
1 .
1 .1 .
1 .1 .1
1 .1 .2
1 .1 .2 .1
1 .1 .2 .2