HTM HTW-V5WD2N8 Manual De Usuario E Instalacion página 111

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

1
1.6
1.7
1.5
1.8
1.3
1.1
1.4 1.2
Coding
Assembly unit
1
Outdoor unit
1.1
Manometer
Pressure relief valve
1.2
Expansion vessel
1.3
Plate heat exchanger
1.4
Backup heater(Customized model)
1.5
Air purge valve
1.6
1.7
Flow switch
P_i: Circulation pump inside the unit
1.8
2
Y-shape filter
Stop valve (field supply)
3
4
Wired controller
Drain valve (field supply)
6
Fill valve (field supply)
7
8
Balance tank (field supply)
Air purge valve
8.1
The volume of balance tank(8) should be greater than 40L(for 5~9kW unit, greater than 20L) The drain valve (6) should
be installed at the lowest positon in the system. An independent backup heater can be selected and installed in the door.
pump(10) should be controlled by outdoor unit and connect to corresponding port in the outdoor unit(refer to 9.7.6
Connection for other components/For outside circulation pump P_o).
Circulation pump operation
The circulation pump (1.8) and (10) will operate as long as the unit is on for space heating.
The circulation pump (1.8) will operate as long as the unit is on for heating domestic hot water (DHW).
Space heating
1) The unit (1) will operate to achieve the target water flow temperature set on the wired controller.
2) The bypass valve should be selected so that at all times the minimum water flow as mentioned in 9.4Water piping is
guaranteed.
Domestic water heating
1) When the domestic water heating mode is enabled (either manually by the user, or automatically through scheduling)
the target domestic hot water temperature will be achieved by a combination of the heat exchanger coil and the electrical
booster heater (when the booster heater in the tank is set to YES).
2) When the domestic hot water temperature is below the user configured set point, the 3-way valve will be activated to
heat the domestic water by means of the heat pump. If there is a huge demand for hot water or a high hot water
temperature setting, the booster heater (12.1) can provide auxiliary heating.
18
2
3
6
7
8
Coding
FHL 1...n
NOTE
106
4
12.1
9
8.1
10
8.2
FHL1
Assembly unit
8.2
Drain valve
9
Expansion vessel (field supply)
P_o: Outside circulation pump (field supply)
10
Collector (field supply)
11
Domestic hot water tank (field supply)
12
12.1
Air purge valve
Heat exchanger coil
12.2
Booster heater
12.3
T5: temperature sensor
13
14
Hot water tap (field supply)
P_d: DHW pump (field supply)
15
One way valve (field supply)
16
Bypass valve (field supply)
17
SV1: 3-way valve (field supply)
18
Floor heating loop (field supply)
/
/
12
14
13
15
12.3
16
12.2
11
17
----
FHL2
----
FHLn