Symptom 8: DHW mode can't change to Heat mode immediately
POSSIBLE CAUSES
Heat exchanger for space
heating not big enough
Space heating load is small
Disinfect function is
enabled but without TBH
Symptom 9: DHW mode heat pump stop work but setpoint not reached, space heating require heat but unit stay in DHW mode
POSSIBLE CAUSES
Surface of coil in the tank
not large enough
TBH or AHS not available
13.3 Operation parameter
This menu is for installer or service engineer reviewing the operation parameter.
At home page, go to ''MENU''>''OPERATION PARAMETER''.
Press ''OK''. There are six pages for the operating parameter as following. Press ''▼ ''、 ''▲'' to scroll.
OPERATION PARAMETER
OPERATE MODE
CURRENT
COMPRESSOR FREQUNCY 24Hz
COMP.RUN TIME1
COMP.RUN TIME2
COMP.RUN TIME3
OPERATION PARAMETER
Ta ROOM TEMP.
Th COMP. SUCTION TEMP.
Tp COMP. DISCHARGE TEMP.
TW_O PLATE W-OUTLET TEMP. 35°C
TW_I PLATE W-INLET TEMP.
P1 COMP.RESSURE
2300kPa
The power consumption parameter is preparatory. some parameter is not be activated in the system, the parameter will
show "--"
The heat pump capacity is for reference only, not used to judge the ability of the unit. The accuracy of sensor is ±1℃.
The flow rates parameters are calculated according to the pump running parameters,the deviation is different at different flow
rates,the maximum of deviation is 25%.
• Set "t_DHWHP_MAX" to minimum value, the suggested value is
60min.
• If circulating pump out of unit is not controlled by unit, try to
connect it to the unit.
• Add 3-way valve at the inlet of fan coil to ensure enough water
flow.
Normal , no need for heating
• Disable disinfect function
• add TBH or AHS for DHW mode
The same solution for Symptom 7
Heat pump will stay in DHW mode untill "t_DHWHP_MAX" reached or
setpoint is reached. Add TBH or AHS for DHW mode,TBH and AHS should
be controlled by the unit.
OPERATION PARAMETER
1/6
COOL
COMP. RUN TIEM4
12A
EXPANSION VALVE
FAN SPEED
54MIN
IDU TARGET FREQUENCY
65MIN
FREQUENCY LIMITED TYPE
10MIN
T1 LEAVING WATER TEMP.
OPERATION PARAMETER
4/6
25°C
T1S' C1 CLIMATE CURVE TEMP.
5°C
T1S2' C2 CLIMATE CURVE TEMP.
75°C
TF MODULE TEMP.
SUPPLY VOLTAGE
30°C
POWER CONSUM.
DC GENERATRIX VOLTAGE
NOTE
162
CORRECTIVE ACTION
CORRECTIVE ACTION
2/6
OPERATION PARAMETER
1000HOUR
T1B CIRCUIT2 WATER TEMP.
200P
T2 PLATE F-OUT TEMP.
600R/MIN
T2B PLATE F-IN TEMP.
46Hz
T3 OUTDOOR EXCHANGE TEMP.
5
T4 OUTDOOR AIR TEMP.
35°C
T5 WATER TANK TEMP.
OPERATION PARAMETER
5/6
35°C
DC GENERATRIX CURRENT
35°C
WATER FLOW
55°C
HEAT PUMP CAPACTIY
230V
HMI SOFTWARE
1000kWh
IDU SOFTWARE
420V
ODU SOFTWARE XX-XX-XXXXXXX
3/6
35°C
35°C
35°C
5°C
5°C
53°C
6/6
18A
1.72M3/H
11.52kW
XX-XX-XXXXXXX
XX-XX-XXXXXXX