Descargar Imprimir esta página

HURNER CNC ECO 1000 2.0 Manual De Instrucciones página 60

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 67
Type of Error
a. Data Input
Input Error
Code Error
b. System and Conditions
System Error
Clock Error
Product to Service/
Service Due
Power Supply Failure at
Last Welding
Ambient Temperature
High
Ambient Temperature
Low
Pressure Sens. Defective The sensor indicated on the display (hydraulic pressure,
Heating Sens. Defective
Temperature Sensor
Defective
Printer not Ready
(only label tag printer)
Download Cancelled
Memory Full
GPS Module not Ready
No GPS Signal
Poor GPS Signal
c. Welding Process
Temperature low
28
EN
Error while entering data with the keypad.
Error while reading data from a bar code or an RFID card.
The welding system has to be disconnected immediately
from both the power supply and the basic machine chassis.
The auto-test has detected an error in the system. The
system must no longer be operated and has to be sent to
an approved shop for check and repair.
The internal clock of the machine is defective; re-set the
clock in the configuration menu.
The recommended next service date for the system is
overdue. The service due message has to be acknowledged
by pressing the START/SET key. Send the welding system to
the manufacturer or an approved service point for service
and check-up.
The last welding is incomplete. The welding system was
disconnected from the power supply voltage while it was
in progress. To go on using the product, this error has to
be acknowledged by pressing the STOP/RESET key.
This error occurs only when the machine is switched on
after the welding operation during which the supply
failure happened. It then has to be reacted to by pressing
the STOP/RESET key.
Outside temperature not within the range from – 20°C
to + 60°C.
Outside temperature not within the range from – 20°C
to + 60°C.
heating element temperature, ambient temperature) is
defective; where possible, check the connections/plug;
have the machine inspected by an authorized service shop
if needed.
The optional printer is not ready (possible reasons also: no
communication or faulty cable).
During data transfer or printing, an error condition
occurred which could not be cleared.
The system memory is full of welding reports. Print or
download the reports in memory or switch memory
control off. Without memory control, a new report
overwrites the oldest existing one.
The minute that you have to wait from switching the GPS
module on to the actual recording of the geo-data is not
over yet.
There is no reliable signal from the relevant satellites to
the GPS antenna of the module.
The signal strength is so weak that no precise position can
be recorded. Repeating the recording is recommended.
The heating element temperature will be increased
automatically.
HÜRNER CNC ECO 1000 2.0 User's Manual
H Ü R N E R S c h w e i s s t e c h n i k G m b H
Description
Nieder-Ohmener Str. 26
35325 Mücke, Germany
Version October 2021

Publicidad

loading