Descargar Imprimir esta página

Waeco AirCon Service Center Instrucciones De Uso página 70

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

First start-up
6.5
Editing default values
The AirConServiceCenter has preset values for the most important
service tasks. The default values appear automatically when you select
the respective menu.
You can alter the following default values if necessary:
Parameter:
Pressure increase Test time min.
Vacuum Time min.
Leak test min.
PAG Oil ml.
UV Tracer ml.
Filling Qt. g.
Print recovery value?
Refrigerant analysis (ASC2000RPA only)
Nitrogen Test (nur ASC2000RPA only)
1. In standby mode, use the cursor keys
"Other selections":
2. Press ENTER to confirm.
3. Use the cursor key
4. Press ENTER to confirm.
5. Enter the password "7388".
6. Use the keypad and the cursor keys to enter the information.
7. Press ENTER to confirm.
8. Press STOP to go to standby mode.
70
Short selection
Free selection
Other selections
ENTER-OK
to select "Service".
Default value:
5
20
4
10
7
500
Yes
Yes
Yes
or
to select
AirConServiceCenter

Publicidad

loading

Este manual también es adecuado para:

Asc 1000Asc 2000Asc 2000 rpaAsc 3000