Descargar Imprimir esta página

Waeco AirCon Service Center Instrucciones De Uso página 87

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

7.6
Free selection
The "Free selection" menu is used to conduct air conditioning servicing
step-by-step. You can perform the same processes as in the short
selection menu, but also omit individual procedures. In addition, it is
possible to enter the values for each individual process using the keypad.
You can also enter the vehicle data for the service report in this menu.
The following three processes can be run in isolation from the
"Free selection" menu:
Recycling phase: sampling and analysis of the refrigerant
(ASC2000RPA only), extraction, recycling of refrigerant,
pressure rise test, draining used oil.
Vacuum phase: nitrogen test (ASC2000RPA only), leak test /
overpressure check (ASC2000RPA only), evacuation of the system,
leak test / vacuum check.
Filling phase: filling with fresh oil, filling of UV additive, filling of
refrigerant.
After each process has been performed, a service report is printed.
1. First fit the connections of the AirConServiceCenter to the vehicle
air conditioning system and open them.
2. In standby mode, use the cursor keys
"Free selection":
3. Press ENTER to confirm.
4. Then follow the instructions in the display:
Select the setting (which then flashes) and press ENTER to confirm.
5. If necessary, enter the desired data with the keypad and cursor keys
and press ENTER to confirm.
If you do not want to enter any data here press ENTER to advance to
the next program step.
If the refrigerant has been contaminated (analysis only possible with
ASC2000RPA), abort the air conditioning service and use the refrigerant
draining station, WAECO item number 8885200059, to drain the air
conditioning system.
AirConServiceCenter
Short selection
Free selection
Other selections
ENTER-OK
Operation
or
to select
87

Publicidad

loading

Este manual también es adecuado para:

Asc 1000Asc 2000Asc 2000 rpaAsc 3000