Descargar Imprimir esta página

Waeco AirCon Service Center Instrucciones De Uso página 93

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

In order to check the zero points of the scales for the oils and the
UV additive, open the cover flap (20) on the left-hand side and
disconnect the containers from the snap locks:
- Container for new oil (17)
- Container for UV additive (18)
- Container for used oil (19)
5. When the scales are relieved, press ENTER to confirm. The prompt to
take the container off the scales flashes.
✓ Once you have set the zero point, the selection menu for the scales
appears again.
6. Return the containers to the operating positions.
Attach the containers for oil (17) and (19) and for the UV additive (18)
to the snap locks again and close the cover (20).
7. Press STOP twice to go to standby mode.
AirConServiceCenter
20
17
18
19
Service tasks
93

Publicidad

loading

Este manual también es adecuado para:

Asc 1000Asc 2000Asc 2000 rpaAsc 3000