Descargar Imprimir esta página

ANSMANN 1001-0144 Manual De Operación página 15

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 32
triangleSAFETY PRECAUTIONS
• If you are working near a lead-acid battery, there should be someone
within earshot or nearby who can come to your aid.
• Have plenty of fresh water and soap ready in case battery acid
comes into contact with your skin, clothing or eyes.
• Wear full eye protection and protective clothing. Avoid touching your
eyes when you are working near the battery.
• If battery acid comes into contact with your skin or clothing, wash it
off immediately with soap and water. If acid gets into your eyes, rinse
your eyes out immediately for at least 10 minutes with cold running
water and see a doctor immediately.
• Take off personal items made of metal, such as rings, bracelets,
necklaces and watches, when you are working with a lead-acid
battery. A lead-acid battery can create a short-circuit current that
is high enough to weld a ring or similar to metal, which can lead to
serious burns.
1. TECHNICAL DATA
Input voltage:
Protection class:
Protection type:
End-of-charge voltage:
Configurable charging currents:
Battery capacity (charging):
Battery capacity (maintenance charging):
Ambient temperatures:
circle-c NOTE:
No electric vehicles with a built-in battery can be charged with the vehicle battery
charger.
circle-c NOTE:
No jump-starting of 6 V or 12 V batteries is possible.
2. PROPER INTENDED USE
The BC 6-12 V / 4 A is a multi-stage battery charger for vehicles. It is used for
charging and maintenance charging 6 V and 12 V lead batteries (WET, AGM and gel).
It can also charge 12 V lithium iron phosphate batteries (LiFePO
ing program intended for this. Alternatively, the charger can also be used in Supply
mode as a power supply, e.g. in order to retain electrical settings when the battery is
disconnected. However, the charger is not suitable for charging lithium-ion batter-
ies.
Discharged batteries can also be regenerated, but this depends on the type of
battery. Read the manual carefully before using the charger for the first time, and
keep it safe.
DE
|
EN
| FR | ES | PT | SE | IT | NL | DK | FI | NO | PL
220-240 V AC / 50 Hz
II
IP65
6 V STD: 7.2 V
12 V STD & 12 V M: 14.4 V
12 V AGM/C: 14.8 V
12 V LFP: 14.6 V / RECOND: 16.5 V
4 A (12 V STD, AGM/C, LFP)
2 A (6 V STD)
1.5 A (Recond)
1 A (12 V M)
15 Ah - 120 Ah (4 A)
7 Ah - 120 Ah (2 A)
5 Ah - 120 Ah (1.5 A)
4 Ah - 120 Ah (1 A)
4 Ah – 200 Ah
-20°C - +40°C
, LFP) in the charg-