2.2
Charging Indications
Table 6: Charging Indications
Charger Indication
Solid green for 1 second
Solid red
Blinking green
Solid green
Blinking red
Blinking amber
2.3
Combining the Multi-Unit Chargers
Prerequisites: The maximum number of multi-unit charger that can be combined is two.
Procedure:
1. Place the chargers on the table for support before combining them.
2. To extend the connector, press and push the male connector latch to the left.
Description
Charger power up successfully.
Battery is charging rapidly.
Battery is charged up to 90% or greater capacity.
Battery is charged to 95% or greater capacity.
Battery is at fault.
NOTE: Remove and re-insert the battery to the
charger pocket.
Battery is in standby mode waiting to be charged.
NOTE: Battery might be too hot, too cold, or low
voltage.
MN010173A01-AA
Chapter 2: Charger Operations
11