Comunicación OPC UA
9.3 Uso de la CPU S7-1500 como servidor OPC UA
Tabla 9- 8
Códigos de error de la OPC Foundation
Número de
Nombre
error (hex)
406C0000
UncertainReferenceOutOf-
Server
408F0000
UncertainNoCommunica-
tionLastUsableValue
40900000
UncertainLastUsableValue
40910000
UncertainSubstituteValue
40920000
UncertainInitialValue
40930000
UncertainSensorNotAccurate The value is at one of the sensor limits.
40940000
UncertainEngineeringUni-
tsExceeded
40950000
UncertainSubNormal
40A40000
UncertainDataSubNormal
40BC0000
UncertainReferenceNotDele-
ted
40C00000
UncertainNotAllNodesAvai-
lable
40DE0000
UncertainDominantVa-
lueChanged
40E20000
UncertainDependentVa-
lueChanged
Tabla 9- 9
Códigos de error de la OPC Foundation
Número de
Nombre
error (hex)
80010000
BadUnexpectedError
80020000
BadInternalError
80030000
BadOutOfMemory
80040000
BadResourceUnavailable
80050000
BadCommunicationError
80060000
BadEncodingError
80070000
BadDecodingError
80080000
BadEncodingLimits-
Exceeded
80090000
BadUnknownResponse
80B80000
BadRequestTooLarge
210
Estado "Uncertain" (4000_0000 - 7FFF_FFFF)
Significado
One of the references to follow in the relative path references to a node in
the address space in another server.
Communication to the data source has failed. The variable value is the last
value that had a good quality.
Whatever was updating this value has stopped doing so.
The value is an operational value that was manually overwritten.
The value is an initial value for a variable that normally receives its value
from another variable.
The value is outside of the range of values defined for this parameter.
The value is derived from multiple sources and has less than the required
number of Good sources.
The value is derived from multiple values and has less than the required
number of Good values.
The server was not able to delete all target references.
The list of references may not be complete because the underlying system
is not available.
The related EngineeringUnit has been changed but the Variable Value is still
provided based on the previous unit.
A dependent value has been changed but the change has not been applied
to the device. The quality of the dominant variable is uncertain.
Estado "Bad" (8000_0000 - FFFF_FFFF)
Significado
An unexpected error occurred
An internal error occurred as a result of a programming or configuration
error.
Not enough memory to complete the operation.
An operating system resource is not available
A low level communication error occurred.
Encoding halted because of invalid data in the objects being serialized.
Decoding halted because of invalid data in the stream.
The message encoding/decoding limits imposed by the stack have been
exceeded.
An unrecognized response was received from the server.
The request message size exceeds limits set by the server.