Comunicación OPC UA
9.3 Uso de la CPU S7-1500 como servidor OPC UA
Número de
Nombre
error (hex)
80710000
BadHistoryOperationInvalid
80720000
BadHistoryOperation
Unsupported
80730000
BadWriteNotSupported
80740000
BadTypeMismatch
80750000
BadMethodInvalid
80760000
BadArgumentsMissing
80770000
BadTooManySubscriptions
80780000
BadTooManyPublish
Requests
80790000
BadNoSubscription
807A0000
BadSequenceNumber
Unknown
807B0000
BadMessageNotAvailable
807C0000
BadInsufficientClientProfile
80BF0000
BadStateNotActive
807D0000
BadTcpServerTooBusy
807E0000
BadTcpMessageTypeInvalid
807F0000
BadTcpSecureChannel
Unknown
80800000
BadTcpMessageTooLarge
80810000
BadTcpNotEnough
Resources
80820000
BadTcpInternalError
80830000
BadTcpEndpointUrlInvalid
80840000
BadRequestInterrupted
80850000
BadRequestTimeout
80860000
BadSecureChannelClosed
80870000
BadSecureChannelToken
Unknown
80880000
BadSequenceNumberInvalid The sequence number is not valid.
80890000
BadConfigurationError
808A0000
BadNotConnected
808B0000
BadDeviceFailure
808C0000
BadSensorFailure
808D0000
BadOutOfService
214
Estado "Bad" (8000_0000 - FFFF_FFFF)
Significado
The history details parameter is not valid.
The server does not support the requested operation.
The server not does support writing the combination of value, status and
timestamps provided.
The value supplied for the attribute is not of the same type as the attribute's
value.
The method id does not refer to a method for the specified object.
The client did not specify all of the input arguments for the method.
The server has reached its maximum number of subscriptions.
The server has reached the maximum number of queued publish requests.
There is no subscription available for this session.
The sequence number is unknown to the server.
The requested notification message is no longer available.
The Client of the current Session does not support one or more Profiles that
are necessary for the Subscription.
The sub-state machine is not currently active.
The server cannot process the request because it is too busy.
The type of the message specified in the header invalid.
The SecureChannelId and/or TokenId are not currently in use.
The size of the message specified in the header is too large.
There are not enough resources to process the request.
An internal error occurred.
The Server does not recognize the QueryString specified.
The request could not be sent because of a network interruption.
Timeout occurred while processing the request.
The secure channel has been closed.
The token has expired or is not recognized.
There is a problem with the configuration that affects the usefulness of the
value.
The variable should receive its value from another variable, but has never
been configured to do so.
There has been a failure in the device/data source that generates the value
that has affected the value.
There has been a failure in the sensor from which the value is derived by the
device/data source.
The source of the data is not operational.
Manual de funciones, 12/2017, A5E03735817-AF