Descargar Imprimir esta página

Generac iX 1600 Manual Del Propietário página 15

Ocultar thumbs Ver también para iX 1600:

Publicidad

Idiomas disponibles

Idiomas disponibles

TROUBLESHOOTING
GUIDE
Enginewon't start.
1. No fuel in tank.
2. Fuelvalveturned off.
3. Defectivespark plug.
4. Pluggedfuel filter.
5. Defectiveor stuck engine stop switch.
1. Add fuel to tank.
2. Turn fuel valve on.
3. Replacespark plug.
4. Replacefuel filter.
5. Replaceengine start switch.
=
Enginestarts, then shuts down.
1. Low fuel level.
2. Fueltank vent closed.
3. Incorrect engine oil level.
4. Contaminatedfuel.
5. Defectivelow oil level switch.
6. Defectiveignition coil.
1. Add fuel to tank.
2. Openfuel tank vent.
3. Checkengine oil level, add or drain as needed.
4. Replacefuel filter.
5. ReplaceLow Oil Level switch.
6. Replaceignition coil.
Enginestarts, then runs rough.*
1. Choke is stuck or left on.
2. Dirty or clogged air filter.
3. Defectiveor dirty spark plug.
4. Dirty fuel filter.
5. DefectiveEcoModeswitch.
1. Turn choke off.
2. Cleanor replacethe air filter element.
3. Replacespark plug.
4. Replacefuel and fuel filter.
5. ReplaceEcoMode switch.
I
I
No AC output.
1. Generatoris overloaded(OVERLOAD LED is on
1. Shutdown generatorto reset module. Reduce
and READYLEDis flashing, Seecontrol Panel
loads andrestart generator.
Identification section).
2. AC voltage is low (OVERLOAD LED is on and
2. Verify that the choke is OFF.
READYLEDis flashing, Seecontrol Panel
Identification section).
3. Inverter module is overheated (OVERLOAD LEDis
3. Verify service door is ON.Let cool for 15 minutes
on and READYLEDis flashing, Seecontrol Panel
and restart generator.
Identification section).
4. Short circuit in electrical device (OVERLOAD LED
4. Verify condition of any extensioncords and all
is on and READYLEDis flashing, Seecontrol Panel
items being powered.
Identification section).
5. Defectiveinverter assembly.
5. Replaceinverter assembly.
No DC output. **
1. DC circuit breaker is open.
1. Reset DCcircuit breaker.
2. DefectiveDC circuit breaker.
2. ReplaceDC circuit breaker.
3. Defectiverectifier.
3. Replacerectifier.
Fuelleaks from drain hoses.
1. Fuelsystem over primed (flooded).
1. Let generatorsit 15 minutes before restarting.
2. Carburetordrain in bowl is not closed.
2. Turn valve clockwise to close.
* Enginespeed increases and decreases-- This is normal as the generatorstarts up and as loads vary.
** Verify EcoMode Switch is in the "0" OFFposition.
13