Notes about the protection circuits
This unit has a DC voltage protection circuit, an overcurrent protec-
tion circuit and an overheating protection circuit built-in.
o If the DC voltage protection circuit is activated, the unit will imme-
diately enter standby.
When the overcurrent protection circuit or the overheating protec-
tion circuit is operating, the power indicator blinks and one of the
following error messages blinks on the display.
Overload!
The overcurrent protection circuit is active.
If this error continues for 30 seconds or more, the unit will enter
standby.
Since a short could be occurring with a speaker cable + and −, put
the unit into standby and check the speaker connections.
Over TEMP!
The overheating protection circuit is active.
If this error continues for 30 seconds or more, the unit will enter
standby.
Since the internal temperature has become high, put the unit in
standby and wait a while for the temperature to decrease. You can
also change the installation conditions to improve ventilation.
o The overheating protection circuit could be activated again if
the power button is used while the internal temperature is still
high.
If a protection circuit activates again even after the cause of its activa-
tion has been resolved, there could be an issue inside the unit, for
example.
Disconnect the power cord from the outlet and contact the store
where you purchased the unit.
28
Troubleshooting
If you experience a problem with this product, please take a moment
to review the following information before requesting service.
Moreover, the problem might be caused by something other than
this unit. Please also check the operation of the connected units.
If this product still does not operate correctly, contact the retailer
where you purchased it.
The unit does not turn on.
e Check that the power cord is plugged into a working power
outlet.
e Check that the power cord is properly connected to this unit.
Standby mode starts automatically.
e If the unit enters standby after "POWER OFF" appears, the auto-
matic power saving function is operating to put the unit into
standby.
Press the INPUT knob until the power indicator lights to turn
the unit on.
Change the automatic power saving setting if necessary
(page 25).
e If the unit enters standby without "POWER OFF" appearing, the
DC voltage protection circuit is operating.
Contact the store where you purchased the unit.
Remote control does not work.
e Turn the main unit on (page 18).
e If the batteries are exhausted, replace both of them with new
ones (page 16).
e The remote control will not work if there is an obstruction
between it and the main unit. Point the remote control toward
the main unit and use it within 7  m (23  ft) of the front panel
(page 15).
A television or other device is operating improperly.
e The use of this unit's remote control might cause some televi-
sions and other devices with wireless remote control functions
to operate incorrectly.
VOLUME knob does not work.
e The VOLUME knob will not affect input sources set to THRU>
(page 26).
An error message appears.
e A protection circuit is active. Put the unit into standby and
eliminate the cause (page 28).
e A short might have occurred with the +/− speaker cables.
Check the speaker cable connections (page 10).
The stereo sound position is irregular.
e Check that neither of the speakers has a connection cable with
+/− reversed.
This unit uses a microprocessor, so noise and other external
interference could cause it to stop functioning properly. If
this occurs, put the unit into standby mode, disconnect the
power cord from the outlet, and wait about one minute before
restarting operation from the beginning.

Publicidad

loading

Este manual también es adecuado para:

F-02