Pentair 368 Manual De Instrucciones página 18

Ocultar thumbs Ver también para 368:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 42
NOTE: If the brine tank has a salt grid, wait until the Refill Cycle (C7) is completed and
the valve has returned to the service position. Ensure the water level is approximately
25 mm above the salt grid. If the water level is less than 25 mm above the grid, then
adjust its height so that the level of water above the salt grid is approximately 25 mm.
5. C hecking Regenerant Draw.
A. F rom the service position press and hold button for 5 seconds to initiate an immediate manual
regeneration.
B. T he control will begin a manual regen and advance the control valve to the backwash cycle (C1).
Press the and buttons to advance to the regenerant draw slow rinse cycle (C2)
C. O bserve that water is being drawn from the regenerant tank. If the water level does not recede, check
all regenerant line connections.
6. I f the water level is receding from the regenerant tank press the and buttons for 3 seconds to cycle
the control back to the service position.
7. T urn on a faucet plumbed after the water conditioner. Run the faucet until the water runs clear.
8. Place regenerant material in the brine tank.
WARNING: Ensure that the system has been properly disinfected per the water condi-
tioning system manufacturer's recommendations.
The Water Conditioning System is Now Fully Operational
The display will show the hour of the day. The decimal point at bottom center of the display will blink
when water is flowing..
18
Rev B
Pentair Residential Filtration, LLC

Hide quick links:

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido