Installation
Drain Line Flow Control
The drain line flow control (DLFC) requires assembly (Figure 5).
1. Locate parts and a roll of Teflon tape. The plumbing adapters should be removed (Figure 7
Connector Assembly).
2. Wrap the tape over threads of the flow control.
3. Screw the flow control and the 90° elbow together. Hand tighten.
4. Place the ball into the flow control and insert the assembly into the drain line opening.
5. Push the assembly in and secure with the drain line clip.
6
Rev B
Figure 4
Figure 5