Descargar Imprimir esta página

Saf-Fro DVU W500 Instrucciones De Funcionamiento Y Mantenimiento página 16

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 40
EN
Fault list description :
Code
Message LCD
E03
Over max pw
E07
Overvoltage pw
E07
Undervoltage pw
E15
Max aver current
E16
Max strikcurrent
E25
Over duty cycle
E30
Missed striking
E32
Broken arc
E33
Program problem
E33
Incompat. prog.
E33
Incompat. conf.
E33
Corrupted prog.
E33
Corrupted conf.
E33
Corrupted list
E42
Device reset
E42
Unstable pow sup
E44
Calibration
E45
Instant stop
E49
Check device cnt
E50
Cooling problem
E52
Stuck electrod
E53
Stuck wire
E63
Motor torque
Not present Syn
E72
E80
I min control
E81
I max control
E82
U min control
E83
U max control
E84
Wf I motor max
E85
Wf I motor min
E86
Missing software
E90
Error CAN bus
Exceeding the maximum allowed power from the current source – check that the welding program
parameters do not exceed the characteristics of the current source (including Free mode)
Over voltage of the 3 phase power supply of the power source of (tolerance 400V - 3 ~ 15 %/-20 %) -
Verify the characteristics of the power supply
Under voltage of the 3 phase power supply of the power source of (tolerance 400V - 3 ~ 15 %/-20 %) -
Verify the characteristics of the power supply
Overtaking of the maximum average current authorized by the power source - verify that the parameters of
the program of welding do not exceed the characteristics of the power source (Free mode in particular)
Overtaking of the maximum instant current authorized by the power source - verify that the parameters of
the program of welding do not exceed the characteristics of the power source (Free mode in particular)
Overtaking of the duty cycle of the power source – wait for the cooling of the power source
Automatic mode only
Time out of 3 seconds after the welding launch without detecting striking
Automatic mode only
Detection of arc break
Call of a non authorised or non existing program
The program is not compatible with this software version. Please upgrade the software version of the
power source.
The configuration is not compatible with this software version. Please upgrade the software version of the
power source.
A program is corrupted. This program is visible in the programs management page of the power source. A
removal of the program is required.
The installation configuration is corrupted. Please configure again the installation.
A program list is corrupted. Please configure again the program lists.
A peripheral has been reset. Please restart the power source.
The power supply is unstable. Please check the electrical wiring.
Impossible to achieve the automatic calibration
Check that the procedure of calibration displayed on the screen is well respected
Immediate request from user to stop the welding
No communication with a peripheral.
Check the peripheral connection.
It is imperative to connect and disconnect the wire feeder when the installation is out of power.
Flow problem of the cooling unit
MMA only
Detection of the sticking of the electrode with the workpiece. Unstick the electrode
MIG only
Detection of the sticking of the wire with the workpiece. Cut the wire
Excessive torque of the wire feeder motor.
Check that the wire sheathing is clean and that nothing is blocking the motor advance or the wire feeding
movement
Check that the tightness of the rollers is not too important
Launching of a welding program where user synergy is not present in the generator – import or define the
user synergy corresponding to the current program
Overtaking of the low threshold of welding current monitoring defined by the user
Overtaking of the high threshold of welding current monitoring defined by the user
Overtaking of the low threshold of welding voltage monitoring defined by the user
Overtaking of the high threshold of welding voltage monitoring defined by the user
Overtaking of the low threshold of wire feeder motor current monitoring defined by the user
Overtaking of the high threshold of wire feeder motor current monitoring defined by the user
Software is missing for a dedicated peripheral. Please perform again a software upgrade.
The communication with a peripheral is highly disturbed. Please check the peripheral connection.
It is imperative to connect and disconnect the wire feeder when the installation is out of power
Signification
15

Publicidad

loading

Este manual también es adecuado para:

W000372327