It is designed for professionals involved, for
example, in work in elevator shafts or on
façades.
Press on «» to lift and on «» to lower.
Release the buttons to stop the movement.
If it is not stopped, press the Emergency
Stop. If it is not working, remove the main
plug and have your hoist maintained.
2.5
Decommissioning
After work, or during an prolonged shutdown, or if
preventive maintenance tests (see §3) are not
satisfactory, put your load on the floor or a secure
access level. Disconnect the hook from the load
when it is resting stable on a fixed and solid
support.
The device can remain attached provided that it is
protected from the weather and in a dry place.
Snap your emergency stop.
Unplug and store your pendant control box.
Store your power supply cable.
2.6
Warnings about contraindications
It is forbidden to use this product:
- if you are not a trained professional
- to exert a force or lift a load greater than the
WLL if it is not described in this manual,
- to lift people,
- in harsh conditions (extreme or corrosive
environment, high magnetic fields, etc.)
- in potentially explosive atmospheres
- to perform work on energized power lines,
- to carry loads themselves dangerous (molten
metals, acids, bases, radioactive material,
fragile loads etc.)
- in combination with other lifting equipment if
it is not listed in this instruction manual,
- with loads with a wind surface area >2 m² if it
is not listed in this manual,
- with a wireless remote control system not
mentioned in this manual
- in the event of specific risks (wind> 14 m / s,
T ° <-10 ° C or> 55 ° C, storms etc.)
- with worn or deformed cables
- with
lubricated
containing bisulphite or MoS2 (Molykote ®,
etc.)
- To apply a load on the loose strand of the
hoist.
INSTRUCTION MANUAL
Electrical winches MOTRIX types 526&527
cables
with
products
- To use the wire rope as a means to sling the
load
2.7
Residual risks
The use of cable damaged or not suited to the
device is the major risk of accident and failure.
Check that your equipment has not been
subject to vandalism, theft, or damage.
Never disable the safety features.
Never swing a load voluntarily.
Do not block a control.
In case of continuous operation for more
than 30 ', the surface temperature of the motor can
begin to rise significantly.
Interrupt the use for 15 to 20 min.
2.8
Transportation, handling, storage
To transport your machine from one site to another,
remove the cable from your hoist.
Store the various components of your equipment in
a clean and dry place.
Ref: 1813000210
Page: 13/21
Version: 42/22