The cables must be replaced in the following cases:
- More than 10 wires broken over a length of
25 cm.
- "Basket" deformation or rupture of one of the
cable strands.
- Cable crushed, unravelling.
- Considerable oxidation
When using plastic return pulleys, they must be
replaced once they have been used with cables
having at least one broken wire.
3.1.4 Setting of the overload (except hoist type
527B)
The
A
measuring the current consumed
during the upward movement.
B
Threshold adjustment can only
be performed by a qualified
electrician
C
specialized
"Factory" presets are:
D
526J
Over – Latch
A
1sec – 5A
B
C
85 - 95%
D
INSTRUCTION MANUAL
Electrical winches MOTRIX types 526&527
sensor
operates
in
a
workshop
in
winches.
527D/527E
527N
1sec – 10A
60 - 70%
100%
1sec
The setting of the threshold is done on the button C,
on a test bench and with loads clearly identified.
Hang the desired overload: for example 1100kg +
25% = 1375kg.
Press UP and turn knob C counterclockwise until
the motion is stopped.
Restart and press DOWN.
Remove the excess load and check for proper
operation while pressing UP.
Never set this sensor to lift a load greater
than WLL.
by
Ref: 1813000210
Page: 15/21
Version: 42/22