Use In Accordance With The Intended Purpose - Kemper MaxiFil Clean Manual De Uso

Ocultar thumbs Ver también para MaxiFil Clean:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 147
3.2

Use in accordance with the intended purpose

The MaxiFil Clean device is designed to exhaust welding fumes generated during
electric arc welding at the place of their origination and filter out these fumes. In
principle, the device can be used for all procedures during which welding fumes are
released. However, you must prevent sucking a "shower of sparks" into the filtration
unit, for example during the grinding process.
Welding fumes released during the procedure are captured by the exhaust nozzle.
They are then brought into the filter unit together with the exhausted air. Here they
are guided through two-stage filtration consisting of an upstream rotating separator
and a filtration cartridge, in which even the finest fume particles are separated with a
separation degree of 99.9%, which could get into your lungs. The cleaned air is
sucked by the fan and conveyed back into the workspace.
For the extraction of welding fumes containing carcinogenic particles created
during welding of alloy steels (e.g., stainless steel), according to official
regulations, only units which have been tested and approved may be operated
in the so-called air circulation process. This filter unit is approved for the
extraction of welding fumes generated during welding of low and high-alloyed
steels and meets the requirements of the welding smoke separation class W3,
according to DIN EN ISO 15012-1.
NOTE
When extrac ting welding fumes c ontaining carcinogenic ingredients (e.g.,
chromates , nickel oxides , etc.) the requirements of T R G S 560 (T echnical R ules for
Hazardous S ubs tances ) and T R G S 528 (Welding Works ) mus t be complied with.
The technical specifications also include dimensions and other information about
the MaxiFil Clean device, which shall be considered.
NOTE
Observe the data in paragraph 9.1 Technical data. It is imperative that this
data be adhered to.
To ensure use in accordance with the intended purpose, instructions
regarding
− safety,
− operation and management,
− maintenance and repairs,
described in this instruction manual shall also be adhered to.
Other or broader use is deemed contrary to the intended purpose. Such
damages fall within the exclusive liability of the MaxiFil Clean device operator.
The same applies to making arbitrary modifications to the welding fumes filter.
KEMPER MaxiFil Clean Instruction manual - EN
- 48 –
Technical changes and errors reserved.

Publicidad

Tabla de contenido
loading

Tabla de contenido