Troubleshooting

Failure
All fumes cannot
be collected.
The horn sounds
Dust leak on the
clean air side.
The protective
motor relay (F4)
was activated.
The device cannot
be started.
KEMPER MaxiFil Clean Instruction manual - EN
Possible cause
The distance of the exhaust nozzle
from the welding point is too large.
The clean air vent is covered.
The suction power is too low, the
throttling valve in the exhaust nozzle
is closed.
The filtration cartridge (109 0476)
is saturated.
The filtration cartridge (109 0476)
is damaged.
Clogged suction filter (motor
temperature too high)
No voltage.
The maximum filling capacity of the
dust collection filter has been reached
The Start/Stop sensor is connected,
however, it does not recognize the
current (no welding under process
yet)
- 67 –
Technical changes and errors reserved.
Corrective actions
Slide the exhaust
nozzle closer.
Uncover the clean air
vent.
Fully open the control
valve in the exhaust
nozzle.
Replace the filter
cartridge.
(KEMPER Service)
Replace the filter
cartridge.
(KEMPER Service)
Allow the device to cool
off and/or replace the
suction filter.
Call an electrician.
Replace the dust
collection tank
Start the welding
process.