Ocultar thumbs Ver también para MaxiFil Clean:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 147
7.1

Care

Caring for the MaxiFil Clean device is essentially limited to the cleaning of all
surfaces from dust and deposits and inspecting the filter elements.
CAUTION
Skin contact with the smoke originating from cutting, etc. may
result in irritation in sensitive individuals!
Risk of severe damage to the respiratory organs and respiratory
system!
In order to avoid contact and inhalation of dust, use protective
clothing, gloves and breathing apparatuses with fans such as
KEMPER autoflowXP or respiratory mask with an FFP2 class filter
according to EN 149.
Prevent the release of harmful dust when cleaning the device to
avoid damage caused to the health of persons not appointed to
perform work.
NOTE
Do not clean the MaxiFil Clean device with compressed air!
Dust and dirt could get into the ambient air.
Taking adequate care of the MaxiFil Clean device will contribute to maintaining it in
working order for long-term period.
Clean the MaxiFil Clean device thoroughly once a month.
When cleaning the exhaust arm, also remove the accumulated dust or other
deposits on the protective grid (optional accessory), or inside the exhaust nozzle
respectively.
The MaxiFil Clean device external surface can be cleaned using an appropriate
vacuum cleaner classified under dust class H or alternatively wiped with a damp
cloth.
Check the hose of the exhaust arm for damage such as spark holes or worn
spots.
KEMPER MaxiFil Clean Instruction manual - EN
- 61 –
Technical changes and errors reserved.

Publicidad

Tabla de contenido
loading

Tabla de contenido