6.3
Adjusting the position of the extraction nozzle
The exhaust arm, or exhaust nozzle respectively, are designed to ensure easy
manual adjustment and a closer approach. At the same time, the exhaust nozzle is
automatically kept in the set position. Furthermore, both the exhaust nozzle and the
exhaust arm rotate by 360 degrees so they can be adjusted to almost any position.
To ensure the sufficient suction of welding fumes, it is important for the exhaust
nozzle to always be in the correct position. The correct position is shown in the
following picture.
− Adjust the position of the exhaust arm so that the exhaust nozzle is located at
an angle and about 25 cm above the point of welding.
− The exhaust nozzle must be set so that, with regard to the thermally
conditioned movement of welding fumes and suction reach, it safely sucks all
welding fumes.
− Always place the exhaust nozzle close enough to the relevant welding point.
CAUTION
The incorrect placement of exhaust nozzle or insufficient suction power
does not guarantee the sufficient suction of air containing hazardous
substances via the exhaust nozzle. Hazardous substances can thus reach
the user's respiratory system and lead to injury!
6.4
Commissioning
• Connect the filter unit to the local voltage supply. "Pay attention to the
identification label"
• Connect the filter unit to the local compressed air supply. Required
compresses air 5-6 bar, clean, dry and oil-free, also see Technical Data.
• Switch the device on using the button identified with the "0" and "I" symbols.
• The fan will start-up and the green indicator light on the device button
indicates the trouble-free operation of the device.
• The exhaust nozzle must additionally be adjusted, depending on the stage of
the procedure.
KEMPER MaxiFil Clean Instruction manual - EN
- 59 –
Technical changes and errors reserved.