Wacker Neuson GPS9700A Manual Del Operador página 47

Generador portátil

Publicidad

Idiomas disponibles

Idiomas disponibles

GPS9700A
6
Troubleshooting
Problem / Symptom
If engine doesn't start, check that:
If engine starts but there is no power
at receptacles, check that:
If the GFCI trips when a load is
connected, check that:
wc_tx004603en.fm
Reason / Remedy
Engine switch is on Start.
Fuel valve is open.
Fuel tank has fuel.
Sediment cup is clean.
Choke lever is in correct position. Choke should be closed
when starting a cold engine.
All loads are disconnected from generator.
Spark plug is in good condition.
Spark plug cap is tight.
Engine oil level is adequate.
Battery is charged and connected properly.
Circuit breaker is closed.
Connector from generator to control panel is tight.
Check voltage regulator circuits.
The connected equipment may be wired incorrectly or faulty.
Contact equipment supplier.
See Determining Power Requirements.
47