Oven rack installation (continued)
To remove and reposition the rack, lift the front of both rails, then lift and pull the rails towards you. Then lift the back of the
rails and reposition the rack on the new level.
Electrical Requirement
Your appliance must be electrically grounded in accordance with local codes or, in the absence of local codes, in
accordance with the National Electrical Code (ANSI/NFPA 70, latest edition). In Canada, electrical grounding must be in
accordance with the current CSA C22.1 Canadian Electrical Code Part 1 and/or local codes.
The power supply must be the correct polarity. Reverse polarity will result in continuous sparking of the electrodes, even
after flame ignition. If there is any doubt as to whether the power supply has the correct polarity or grounded, have it
checked by a qualified electrician.
Performance may be compromised if the electrical supply is less than 240 volts. The oven is supplied with a conduit
consisting of two insulated hot lead conductors and a bare ground conductor. The wiring diagram covering the control
circuit is provided with the oven.
Electrical Requirement- FBOEL1388-30 (Double Oven)
Electrical Supply
Service
Conduit
Total Amps
Max connected load
Electrical Requirement- FBOEL1371-30 (Single Oven)
Electrical Supply
Service
Conduit
Total Amps
Max connected load
Grounded, 240 VAC, 60Hz
50 amp dedicated circuit
63" (1.6m)
32
7.2kW
Grounded, 240 VAC, 60Hz
30 amp dedicated circuit
63" (1.6m)
16
3.6kW