2)Remove
the two s crews
that secure
the control
panel to the frame.
3)Remove
the control
panel.Tilt
panel forward
and l ift u p and a way from grill. Be careful
not tobreak ordisconnect
the wires for t he c ontrol
panel lights.
Rest the control
panel against
the left side o f t he grill (A) e xposing
the v alves,
burners,
igniter,
and m anifold.
d)'O.
CHECK THE FLEXIBLE
HOSE TO MANIFOLD CONNECTION
The natural gas hose has been attached during the manuafacturing
process. We
do recommend
that the hose to gas manifold connnection
be leak tested, following
guidelines
in this Owner's Guide, prior to barbecue operation.
CHECK FOR GAS LEAKS
DANGER
Do not use an open flame to check for gas leaks. Be sure
there are no sparks
or open flames
in the area while you
check for leaks. Sparks or open flames will result in a fire or
explosion
which can cause serious bodily
injury or death and
damage to property.
WARNING: You should
check for gas leaks every time you
disconnect and reconnect a gas fitting.
Note: All factory-made
connections
have been thoroughly
checked
for gas leaks. The
burners have been flame-tested.
As a safety precaution
however,
you should recheck
all fittings for leaks before using your WebeK gas barbecue.
Shipping
and handling
may loosen or damage a gas fitting.
WARNING:
Perform these leak checks even if your barbecue
was dealer or store assembled.
You will need: a soap and water solution, and a rag or brush to apply it.
Make sure side burner is off (See LEAK CHECK PREPARATION).
Remove valve
control knob and screws. Remove porcelain
top.
To perform leak checks: Slide back the collar of the quick disconnect
(1). Push male
fitting of the hose into the quick disconnect,
and maintain
pressure. Slide the collar
closed (2). If it does not engage or lock, repeat procedure.
Gas will not flow unless the
quick disconnect
is properly engaged.
Turn on gas supply.
Check for leaks by wetting the connections
with the soap and water solution and
watching for bubbles.
If bubbles form or if a bubble grows, there is a leak.
Note: Since some leak test solutions,
including
soap and water, may be slightly
corrosive, all connections
should be rinsed with water after checking
for leaks.
WARNING:
Do not ignite burners
when leak checking.