7 - PANNELLO DI CONTROLLO
7.1 - DISPLAY
When the power supply is enabled, the display will show:
• all the segments for 1 second
• model of the control unit for 1 second
• firmware version for 2 seconds
Panel will be viewed upon completion of this test:
CLOSED CONTACT
OPEN CONTACT
START1
START2
STOP
ST.NC
DOWN
PHOTOCELL
PLEASE NOTE: The display is off when the control unit is in
ENERGY SAVING mode.
The control panel represents the physical status of the terminal
board contacts and of the program mode keys: if the upper vertical
segment is on, the contact is closed; if the lower vertical segment is
on, the contact is open (the above picture shows an instance where
the inputs PHOTOCELL, SAFETY RIBBONS and STOP have all been
correctly connected).
Points being among display digits show the status of programming
push-buttons: as soon as a push-button is pressed, its relevant point
turns on.
The arrows on the left of the display show the state of the start
inputs.
The arrows light when the related input is closed.
Le frecce a destra del display indicano lo stato della barriera:
• The arrow further at the top is illuminated when the barrier is
in opening phase. If it flashes, it indicates that the opening has
been caused from the participation of an emergency device
(obstruction sensor or obstacle detector).
• The center arrow indicates that the barrier is opened in pause. If
it flashes it means that the time counter is active and counting for
the automatic closing.
• The lower arrow is illuminated when the barrier is in phase of
closing. If it flashes it indicates that the closing has been caused
by an interruption of an emergency device (obstruction sensor or
obstacle detector).
- 62 - ENGLISH
OPENING IN PROGRESS
PAUSE (BARRIER OPENED)
CLOSING IN PROGRESS
UP
SAFETY RIBBON
MENU
7.2 - USE OF THE KEYS FOR PROGRAMMING
The control unit functions and times are programmed by means of
a special configuration menu, which can be accessed and explored
h
i
and OK, located on the side of the control
by using the 3 keys,
,
unit display.
PLEASE NOTE: Outside the configuration menu, pressing
h
the
key activates the START command, pressing the
activates the PEDESTRIAN START command.
There are the following three kinds of menu items:
• Function menu
•
Time menu
•
Value menu
Function menu setup
Function menus allow selecting a function from among a group of
available options. When you enter into a function menu, the current
active option will be viewed; you can scroll all available options
i
h
through
and
keys. By pressing the OK key, you will activate the
option viewed and you will return to the configuration menu.
Time menu setup
Time menus allow setting a function duration. When you enter into a
time menu, the current setup value will be viewed; the display mode
depends on the current value:
h
• Each time you press
key, current time value increases and each
i
time you press the
key, current time value decreases.
h
• By holding down the
key, you can quickly increase the time
value, up to reach the max. value allowed for this item.
• Vice versa, by holding down the
the time value down to reach
• In some circumstances, setting the value to
relevant function is disabled, in this case,
0
of
• By pressing on OK you will confirm the displayed value and you
will return to the configuration menu.
Value menu setup
Value menus are similar to time menus; however, the setup value can
be any number.
h
i
By holding down
or
keys, the value will increase or decrease
slowly.
By pressing on OK you will confirm the displayed value and you will
return to the configuration menu.
The main programming menus of the control unit are shown in the
next pages.
To go through the menus use the three keys
to the following chart:
Press and release the push-button OK
Keep pressed the push-button OK for 2 seconds
Release the push-button OK
Press and release the push-button
Press and release the push-button
i
i
key, you can quickly decrease
0.0"
0
means that the
no
will appear instead
h
i
,
and OK according
h
i
key