PARAMETER VALUE
LP.PA
no
Si
Strt
StAn
no
in.oU
AP.Ch
PrES
oroL
StoP
no
ProS
invE
St.nC
no
FirE
PrES
Foto
no
APCh
CFCh
Ch
- 70 - ENGLISH
DESCRIPTION
Flashing lamp in pause
Function disabled
The flashing lamp works also during the pause time (barrier opened
withactive automatic closing)
Function of input START1 and START2
This menu allows choosing the mode of operation of the input
START1 and START2
Standard mode
The Start input commands on the terminal strip are disabled.
The radio command function depending of the mode
A command on the START1 input of CHANNEL 1 of the receiver
commands opening of the barrier and switch on of the green traffic
light inbound.
A command on the START2 input of CHANNEL 2 of the receiver
controls opening of the barrier and switch on of the green traffic
light outbound
Open/Close mode
Dead Man mode
Clock mode
STOP INPUT
The input STOP is disabled
The STOP command set the barrier idle: on the next successive
command START the barrier resumes the motion in the same
direction
The STOP command sets the barrier idle: on the next successive
START command makes the barrier resume the motion in the
opposite direction to the previous one
ST.NC input function
Input not enabled
Input configured for a fire-prevention alarm. If enabled, the barrier
opens and automatic closure is disabled
Input configured for presence sensor. If enabled, the barrier opens;
when passage is freed, the pause time enables before automatic
closure.
Photocell input
This menu allows programming the behavior in case of participation
of the photocell
Disabled input (the control unit ignores it)
Input always enabled. The interruption of the photocell during the
opening or closing causes the arrest of the barrier.
At reset the barrier resumes the opening movement.
The interruption when in closed barrier inhibits the opening.
Input enabled in closing and with closed barrier.
The interruption of the photocell during the closing causes the
reopening.
Input command enabled only in closing. The interruption of the
photocell during the closing causes the reopening.
ATTENTION: if this option is chosen, it is necessary to
disable the test of photocells
DEFAULT
NUUR4
no
StAn
StAn
no
no
no
DEFAULT
MEMO
NUUR6
no
StAn
no
no
no