PARAMETER VALUE
rA.AP
no - 1 00
rA.Ch
no - 1 00
MFC
1 - 25
no
St .AP
PAUS
ChiU
no
St .Ch
StoP
APEr
St .PA
ChiU
no
PAUS
Ch.AU
no
0.5" - 20'0
Ch.tr
no
0.5" - 20'0
- 68 - ENGLISH
DESCRIPTION
Slow down in opening
This menu allows regulating the percentage of the ride/drive that is
carried out at reduced speed during the last opening stretch
Slow down in closing
This menu allows regulating the percentage of the ride/drive that is
carried out at reduced speed during the last closing stretch
Edge of the limit switch
This menu allows you to establish that an obstacle, even if detected
before pause positioning (barrier open) is however interpreted as a
mechanical stop.
Percentage of the stroke relating to the edge
Function disabled
Start command during the opening phase
This menu allows fixing the control unit conduct in case it receives
a Start command during the opening phase
The barrier closes and enters in pause
The barrier immediately starts to reclose
The barrier continues to open (the command is ignored)
Start command during the closing phase
This menu allows fixing the control unit conduct in case it receives
a Start command during the closing phase
The barrier closes and the cycle is considered concluded
The barrier reopens
Start command during the pause
This menu allows establishing the behavior of the control units if a
Start command is received while the barrier is opened in pause
The barrier starts to reclose
The command is ignored
The pause time becomes recharged (
Automatic Closing
In automatic operation, the control unit automatically recloses the
barrier at the end of the preset time
Function deactivated
The barrier recloses after the time set
Closing after transit
During the automatic operation, the pause count down starts from
the set up value each time a photocell operates during the pause.
If the photocell operates during the opening time, this time will be
immediately stored as pause time.
This function allows having a fast closing after the transit through
the barrier, for which usually a lesser time for
closing) is used
Function deactivated
The barrier recloses after the time set
Ch.AU
)
Ch.AU
(automatic
DEFAULT
DEFAULT
MEMO
NUUR4
NUUR6
40
40
25
25
10
10
PAUS
PAUS
StoP
StoP
ChiU
ChiU
no
no
no
no