PARAMETER VALUE
P.SEr
no - 100
t.PrE
0.5" - 1'00
no
t.P.Ch
0.5" - 1 '00
no
P.AP
30 - 100
P.Ch
30 - 100
Po.AL
10 - 70
rAM
0 - 6
SEn.A
0.0A - 8.0A
no
SEn.C
0.0A - 8.0A
no
DESCRIPTION
Holding magnet power
This menu allows regulating the power with which the
electromagnetic vacuum gripper becomes blocked.
m
ATTENTION: if the holding magnet is not present, set
up this parameter to zero.
NOTE: The locking electromagnet is connected to the accessory
power supply. Hence, it is essential to deactivate the energy saving
function to use it.
Pre-blinking time
Before any barrier movement, blinker will be activated for
time, to warn about the incoming motion
Function deactivated
Different closing pre-flashing time
If this parameter has a value assigned to it, the control unit will
activate pre-flashing prior to closure for the length of time set in
this menu (adjustable time from 0.5" to 1'00)
The closing pre-flashing time corresponds to
Motor power in opening phase
Percentage compared to the maximum motor power
Motor power in closing phase
Percentage compared to the maximum motor power
Motor power during the realignment phase
The realignment phases intervene in the first closure after resetting
and during learning of the limit switches.
Percentage compared to the maximum motor power
Starting ramp
In order not to stress too much the motor, when the motion starts
the power is gradually increased, until reached the set value or
100% if the take-off is enabled.
Higher is the set value, longer the length of time of the ramp, that
is the time necessary to reach the value of nominal power.
Opening obstacles sensor
This menu allows adjustment of sensor sensitivity to obstacles.
When the current absorbed by the motor exceeds the value set,
the control unit detects an alarm.
Detection of an obstacle causes the bar to stop.
Automatic closure is disabled the second time the cycle is
interrupted by an obstacle.
If the obstacle is detected near the limit switch, it is interpreted as
a mechanical stop.
Function deactivated
Closure obstacles sensor
This menu allows adjustment of sensor sensitivity to obstacles.
When the current absorbed by the motor exceeds the value set,
the control unit detects an alarm.
Detection of an obstacle causes complete re-opening, to free the
obstacle. Automatic closure is disabled the second time the cycle
is interrupted by an obstacle.
If the obstacle is detected near the limit switch, it is interpreted as
a mechanical stop.
Function deactivated
DEFAULT
NUUR4
no
1.0"
t.PrE
no
t.PrE
100
70
30
4.0 A
4.0 A
DEFAULT
MEMO
NUUR6
no
1.0"
no
100
70
60
2
4
7.0 A
7.0 A