Descargar Imprimir esta página

TFA GAIA 35.1083 Instrucciones De Uso página 11

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 31
TFA_No_35.1083_Anleit_01_24
Wireless weather station
While in normal mode, press twice the "MIN/MAX" button to enter the
minimum mode.
In the minimum reading mode, press the "+" button to display the fol-
lowing minimum values together with the time and date stamp when
these values were recorded. Press "SET" button while the correspon-
ding minimum value is displayed to reset to the current reading togeth-
er with the current time and date:
• Indoor humidity minimum
• Indoor temperature minimum
• Outdoor humidity minimum
• Outdoor temperature minimum
• Dew point minimum
• Pressure minimum
7.4 Weather forecast
sunny
partly
cloudy
The four weather icons "sunny, partly cloudy, cloudy and rainy" repre-
sent the weather forecast.
The weather forecast symbols indicate an improvement or worsening
of the future weather conditions based on the current weather, which
does not have to correspond exactly with the weather indicated on the
symbol.
7.4.1 Weather forecast tendency indicator
The weather tendency indicators arrow is located between the weather
icons to show the air pressure tendency and provide a forecast of the
weather to be expected by the decreasing or increasing air pressure.
The rightward arrow means that the air pressure is increasing and the
weather is expected to become better. The leftward arrow means that the
air pressure is decreasing and the weather is expected to become worse.
The change of weather forecast icon is in accord to the relationship
between current relative pressure and the pressure change since the
last twelve hours. If the weather is changing, weather tendency indica-
tor (animated arrows) will be flashing. And after the next three hours if
weather conditions have become stable, the arrows will fix indicating a
stable condition happened.
20
18.01.2024
14:45 Uhr
Seite 11
cloudy
rainy
Wireless weather station
Notes to pressure sensitivity setting for weather forecasting:
The pressure threshold can be set to suit the user's requirement for
weather forecasting from 2-4 hPa (default 3 hPa). Areas that experience
frequent changes in air pressure require a higher setting compared to an
area where the air pressure is stagnant. For example if 4 hPa is selected,
then there must be a fall or rise in air pressure of at least 4 hPa before the
weather station will register this as a change in weather.
7.4.2 Storm warning indicator
The storm threshold can be set to suit the user's
requirement for storm forecasting from 5-9 hPa
(default 6 hPa).
When there is a fall over pressure threshold
within 3 hours, the storm forecasting will be acti-
vated, the clouds with rain icon and tendency
arrows will flash for 3 hours indicating the storm
warning feature has been activated.
7.5 Alarm function
The weather station can be programmed in that way that in certain
weather conditions an alarm is activated. For this purpose an upper
(High Alarm) and lower limit (Low Alarm) can be set for many parame-
ters.
While in normal mode press the "ALM" button to enter the High Alarm
mode.
Press the "SET" button to select the following alarm modes. Press "+"
button or "MIN/MAX" button to set the high alarm value. Press and
hold the buttons to change the number in great step.
Press the "ALM" button to choose the alarm on or off. "HI AL" and an
alarm symbol appears or disappears next to the corresponding parame-
ter in the display.
1. Time alarm (hours/minutes, at low alarm setting mode, the same
time alarm setting sequence will repeat)
2. Indoor humidity high alarm
3. Indoor temperature high alarm
4. Outdoor humidity high alarm
5. Outdoor temperature high alarm
6. Dew point
7. Pressure high alarm
While in normal mode press twice the "ALM" button to enter the Low
Alarm mode.
Press the "SET" button to select the following alarm modes. Press "+"
button or "MIN/MAX" button to set the low alarm value. Press and hold
the buttons to change the number in great step.
Press the "ALM" button to choose the alarm on or off. "LO AL" and an
alarm symbol appears or disappears next to the corresponding parame-
ter in the display.