HANDLING AND INSTALLATION
Adjust the fl oor-mounted feet (A) to level the
appliance .
WARNING: The connection opera-
tions must be carried out by qualifi ed per-
sonnel with an acknowledged experience in
the specifi c fi eld, in accordance with the ap-
plicable legislation in the country where the
appliance is installed.
The connection must be carried out with due
care and must comply with all applicable
regulatory and legal requirements. When
the connection is complete and before the
appliance is put into operation, a general
check for any gas leaks is required.
To make the connection, connect the mains
line to the connection pipe of the appliance, fi t-
ting a shut-off tap (A) for the gas supply cut-off
when necessary.
WARNING: The tap (A), which is not
supplied with the appliance, should be in-
stalled in an easily accessible position and
its status (on or off ) must be identifi able at
a glance.
IMPORTANT: The gas supply pipe
must comply with the national requirements
in force and must be periodically checked
and replaced if necessary.
3329590_inst_GB_rev.2
LEVELLING
GAS CONNECTION
HAZARD: Do not connect the appli-
ance to the gas distribution system contain-
ing carbon monoxide or other toxic compo-
nents.
WARNING: The gas feed pipe must
not be longer than 2 metres.