ADJUSTMENTS
ADJUSTING GAS VALVE MINIMUM SETTING (OVEN)
To carry out this operation, proceed as follows.
Close the gas supply tap..
1)
Pull off the knobs (A).
2)
Undo the screws (C) and remove the control
3)
panel (B).
Remove the injector (D) and replace it with
4)
the one suitable for the type of gas in use
(see table at the end of the manual).
Fully screw the injector.
5)
After making the adjustment, seal the screw
6)
with paint.
After completing the operation, fi t the con-
7)
trol panel (B) and the knob (A) back in place.
ADJUSTING THE TOP BURNER PRIMARY AIR (7 KW)
To carry out this operation, proceed as follows.
Close the gas supply tap.
1)
Pull off the knobs (A).
2)
Undo the screws (C) and remove the control
3)
panel (B).
Loosen the screw (D).
4)
Set the burner mount (E) at a distance of 20
5)
mm and fasten the screw (D).
After completing the operation, fi t the con-
6)
trol panel (B) and the knob (A) back in place.
ADJUSTING THE TOP BURNER PRIMARY AIR (10 KW)
To carry out this operation, proceed as follows.
Close the gas supply tap.
1)
Pull off the knobs (A).
2)
Undo the screws (C) and remove the control
3)
panel (B).
Loosen the screw (D).
4)
Set the burner mount (E) at a distance of 20
5)
mm and fasten the screw (D).
After completing the operation, fi t the con-
6)
trol panel (B) and the knob (A) back in place.