4.3 Setting the output type (Single-/Double-Acting)
The typical device configuration of OMFB radio remote controls is to control systems made
up of electric pumps and solenoid valves.
The OMFB Radar II receiver is equipped with a series of 4 microswitches, shown in the
figure: each microswitch allows the installer to set, for each individual output, the function
as double-acting or single-acting, thus it allows the installer to define whether or not the
AUX output must be enabled parallel with each individual output.
In the case of configuration with electric pump, if the microswitch for a given output is
set to OFF (away from the board), the electric pump will not be enabled parallel to this
output; if instead the microswitch is set to ON (thus facing the board), the electric pump
will be enabled parallel to this output.