Descargar Imprimir esta página

HTW UNIG -AAM35DA-R290 Manual De Usuario E Instalacion página 44

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

USER AND INSTALLATION MANUAL
3. INSTALLATION
Fig 2
Fixed plate
4x10mm tapping screw
42
Note:
1.The sealing strip should be pasted along the
edge of the machine, as shown in Figure1.
2. Please peel the striping layer on the sealing
strip gradually while pasting.
3. Paste from the bottom of the machine first.
4. The position of the corner should be pasted as
shown in Figure 2.
5. Improper pasting may cause extra noise.
Lift the unit onto the wall, align the hanging
holes with the hooks on the hanging rail and
gently rest the unit into place.
At the same time, slide the drain pipe through
the drainage hole.
NOTE:
1st: please ensure that the backside of
product is tightly attached on the wall to avoid
additional vibration and noise.
2nd : The end of the external water pipe must
be placed in an open space or drain. Avoid
damage or constriction to the drainage pipe
to ensure the unit drains.
MONOBLOCK UNIG

Publicidad

loading