NOTICE
AND
The California Safe Drinking Water and
Toxic Enforcement Act of i986 (Proposi-
tion 65) requires the Governor of Califor-
nia to publish a list of substancesknown to
the State of California to cause cancer or
reproductive harm,and requires businesses
to warn customers of potential exposures
to such substances.
Users of this appliance are hereby warned
that the burning of gas can result in low-
[eve[ exposure to some of the listed sub-
stances, including benzene, formaldehyde
and soot, due primarily m the incomplete
combustion
of natural gas or liquid petro-
leum
(LP)
fuels. Properly adjusted burners
wiil minimize incomplete
combustion.
Ex-
posure to these substances can also be
minimized by properly venting the burners
to the outdoors.
Users of this applianceare hereby warned
that when the oven is engaged in the serf-
clean cycle, there may be some low level
exposure to some of the listed substances,
including carbon monoxide. Exposure to
these substancescanbe minimized by prop-
eriy venting the oven m the outdoors
during the self-clean cycle by opening a
window and/or door in the room where
the appliance is located.
[HPORTANT
NOTICE REGARDING
PET BIRDS: Never keep pet birds in the
kitchen or in rooms where the fumesfrom
the kitchen could reach. Birds have a very
sensitive respiratory system. Fumes re-
leased during an oven self-cleaning cycle
may be harmful or fatal to birds. Fumes
releaseddue to overheated cooking oil fat,
margarine and overheated non-stick cook-
ware may be equally harmful.
SAVE THESE
NSTRUCT[ONS
FOR FUTURE
REFERENCE
.............
JUCFIN G NFORMATION
]
Jenn-Air's ventilation
system is designed to
capture
both cooking
fumes and smoke
from the cod<top
surface. If the system
does not, these are some ducting ins_iia-
tion situations to check:
° 6" diameter round or 3 I/4"x [ 0" rectan-
gular ducting should be used for duct
lengths [0'-60'. Note: 5" diemeterreuttd
ducting mey be used lithe duct length
is 10' or less.
" No more than three 90° elbows should
be used. Distance between elbows should
be at least two and one half times the
diameter of the duct.
• Recommended Jenn-Air wail cap MUST
be used. Hake sure damper moves freely
when ventilation system is operating.
• There should be a minimum clearance of
6" for cod<top installed near a side wall.
Ifthere is notan obvious improper installa-
tion, there may be a concealed problem
such as a pinched joint, obstruction in the
pipe, etc. Installation is the responsibility of
the installer and questions should be ad-
dressed first by the installer. The installer
should very carefully check the ducting
installation instructions.
° Use the Flow Tester Card ,rovided with
your apF!!znceto check t! _ air flow.
FLOW
TESTER
Thts
enll
of tester
to be
posRIon_l_t
over
_it in_ake,
immllmmmmlamm_lalm