Is a 6000-count handheld true RMS clamp meter with auto range. This full scale overload
protection meter contains the following features:
- AC/DC voltage, AC/DC current, resistance, diode, continuity, capacitance, frequency, duty
ratio, data hold, MAX/MIN, relative.
- LPF (low pass filter) and LoZ (low impedance) voltage.
- Inrush current measurement.
- Analog bar display, Flashlight, NCV, low battery indication, and auto power off.
Warning:
Before using the meter, please read the Safety Instructions carefully.
The meter is designed and manufactured according to IEC61010-1, IEC61010- 2-032
and IEC61010-2-033 safety standards, and conforms to CAT III 1000V, CAT IV 600V, double
insulation, and pollution degree 2.
Note: Before each use, verify meter operation by measuring a known voltage. If the
meter is used in a manner not specified by the manufacturer, the protection provided by the
equipment may not be guaranteed.
1. Before use, please check if there is any item which is damaged or behaving abnormally.
If any abnormal item (such as bare test lead, damaged meter casing, broken LCD, etc.) is
found, or if the meter is considered to be malfunctioning, please do not continue to use the
meter.
2. Do not use the meter if the rear cover or the battery cover is not completely covered up, it
may pose a shock hazard!
3. When using the meter, keep fingers behind the finger guards of the test leads, and do not
touch exposed wires, connectors, unused inputs, or circuits being measured to prevent
electric shock.
4. The function dial should be placed in the correct position before measurement.
5. Do not apply voltage over 1000V between any meter terminal and earth ground to prevent
electric shock or damage to the meter.
6. Use caution when working with voltage above AC 30Vrms, 42Vpeak or DC 60V. Such
voltages pose a shock hazard.
7. Never input voltage or current which exceeds the specified limit. If the range of the measured
value is unknown, the maximum range should be selected.
8. Before measuring the resistance, diode and continuity , switch off the power supply of the
circuit, and fully discharge all capacitors to avoid inaccurate measurement.
9. When the
measurement accuracy. If the meter is not in use for a long time, please remove the batteries.
10.Do not change the internal circuit of the meter to avoid damage to the meter and user!
11.Do not use or store the meter in high temperature, high humidity, flammable, explosive or
strong magnetic field environments.
12.Clean the meter casing with a soft cloth and mild detergent. Do not use abrasives or
solvents!