Measurement result = displayed value – capacitance of open-circuit test leads.
For capacitance ≤1μF, it is recommended to use "REL" measurement mode.
Accuracy guarantee: 5%~100% of range
Frequency/Duty Ratio (Hz%)
Range
10Hz~1 MHZ
10.0%~90.0%
Frequency input amplitude:
10Hz~100kHz: 250mVrms ≤ input amplitude ≤ 20Vrms
100kHz~1MHz: 600mVrms ≤ input amplitude ≤ 20Vrms
Duty ratio:
10%~90%: for square waves of 10Hz~1kHz
30%~70%: for square waves of 1kHz~10kHz
2Vpp ≤input amplitude ≤20Vpp.
Non-contact AC voltage sensing (NCV)
Range
NCV
RELATED MEASUREMENT OF AC CURRENT (PICTURE 1)
30
Resolution
0.01Hz~1K Hz
0.1%
Resolution
Bring the NCV sensor (upper tip) close to
a wire to start sensing. When no voltage
is sensed, the LCD displays "EF". As the
intensity of the detected voltage increases,
more segments "—" will be displayed, and
higher frequently occurs for buzzer and
flashing LED.
OPERATING INSTRUCTIONS
Picture 1
Accuracy
Overload Protection
±(0.1%+3)
±(2.6%+7)
Overload Protection
1000V