IOMM
ProCore Edge North America
4. Installation
4.1. Multi-Charger Installation Schemes
The side-to-side airflow design (Figure 1) requires adequate spacing
between chargers, or other arrangements, for proper operation.
Cool air
Hot air
intake
exhaust
Figure 1 Side-to-Side Airflow Design, Top View
4.1.1. Standard Side-to-Side Charger Spacing
The minimum side-to-side charger spacing, for standard installations,
is 18 in. (46 cm) (Figure 2).
18 in
(46 cm)
Figure 2 Standard Side-to-Side Charger Spacing
Webasto Charging Systems, Inc.
31241-03-0202
11 of 68